Model UT50D: OPERATING MANUAL
Remarks:
l At 20A Range: For continuous measurement
10
seconds and interval not less than 15 minutes.
l Measurement voltage drop: Full range at 200mV.
D. AC Current
Remarks:
l At 20A Range: For continuous measurement
10
seconds and interval not less than 15 minutes.
l Measurement voltage drop: Full range at 200mV.
l Frequency reaponse: 40Hz~400Hz
l Display effective value of sine wave (mean value
response).
Range Resolution Overload ProtectionAccuracy
20mA
200mA
20A
0.01mA
0.1mA
10mA
0.5A. 250V fast type
fuse, 5x20mm
(1%+3)
Un-Fused
(1.8%+3)
(3%+5)
C. DC Current
Range Resolution Overload ProtectionAccuracy
2mA
200mA
20A
0.001mA
0.1mA
10mA
0.5A. 250V fast type
fuse, 5x20mm
(0.8%+1)
(2%+5)
Un-Fused
(1.5%+1)