UNI-T UT206A Spécifications Page 22

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 33
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 21
21
I. Model UT206: Temperature Measurement
(See figure 11)
The temperature measurement range is -40˚C~1000˚C. To measure
temperature, connect the Meter as follows:
1. Insert the red temperature probe into the
HzΩ terminal 
and the black temperature probe into the COM terminal.
2. Set the rotary switch to ˚C.
3. Place the temperature probe to the object being measured.
The measured value shows on the display.
Note
• The Meter automatically displays the temperature value inside the 
Meter when there is no temperature probe connection.
• The included point contact temperature probe can only be used up 
to 250˚C. For any measurement higher than that, the rod type 
temperature probe must be used instead.
• When temperature measurement has been completed, disconnect the 
connection between the testing leads and the circuit under test, and 
remove the testing leads away from the input terminals of the Meter.
Measurement Operation (9)
Model UT205/UT206: OPERATING MANUAL
Vue de la page 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 32 33

Commentaires sur ces manuels

Pas de commentaire