21
Model UT58D: OPERATING MANUAL
Note
l When continuity testing has been completed,
disconnect the connection between the testing leads
and the circuit under test, and remove the testing
leads away from the input terminal of the Meter.
E. Testing for Inductance (see figure 7)
Warning
Make sure the tested inductance is far away from the
high electromagnetic to obtain accurate reading.
( figure 7)
Inductance measurement has 4 measurement positions
on the rotary switch: 2mH, 20mH, 200mH and 20H.
To test for Inductance, connect the Meter as below:
1. According to the size of the tested object’s leads,
insert multi-purpose socket or test clip into the mA
and V terminal.
2. Set the rotary switch to an appropriate measurement
position in HLx range.
3. Insert the tested object into the corresponding jack
of the multi-purpose socket or connect the test clip
to the object being measured.
The measured value shows on the display.