UNI-T UT61 series Spécifications

Naviguer en ligne ou télécharger Spécifications pour Multimètres UNI-T UT61 series. Uni-Trend UT61C multimeter Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 68
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Table of Contents
4
5
6
7
9
10
11
12
13
15
15
18
21
24
26
29
31
33
Title Page
Overview
Unpacking Inspection
Safety Information
Rules For Safe Operation
International Electrical Symbols
The Meter Structure
Rotary Switch
Functional Buttons
Display Symbols
Measurement Operation
A.DC/AC Voltage Measurement
B.DC/AC Current Measurement
C.Measuring Resistance
D.Testing for Continuity
E.Testing Diodes
F.Capacitance Measurement
G.Frequency Measurement
H.Temperature Measurement
Model UT61A/61B/61C/61D/61E: OPERATING MANUAL
1
Vue de la page 0
1 2 3 4 5 6 ... 67 68

Résumé du contenu

Page 1

Table of Contents4567910111213151518212426293133Title PageOverviewUnpacking InspectionSafety InformationRules For Safe OperationInternational Electric

Page 2

The Meter Structure (see figure 1)LCD DisplayFunctional ButtonsBlue buttonRotary SwitchInput Terminal:figure 112345Model UT61A/61B/61C/61D/61E: OPERAT

Page 3

Rotary SwitchBelow table indicated for information about the rotary switch positions.AC and DC Voltage MeasurementAC Voltage Measurement (UT61D only)D

Page 4

Functional ButtonsBelow table indicated for information about the functional button operations.Press to select the maximum and minimum value.Operation

Page 5 - Unpacking Inspection

Display SymbolsMeaningData hold is active.Sleep Mode indicatorIndicates negative reading.Indicator for AC measurementIndicator for DC measurementThe M

Page 6 - Safety Information

NoThe REL is on to display the stored value minus the present value.: Ohm. The unit of resistance.k : kilohm. 1 x 103 or 1000 ohms.M : Megaohm. 1 x

Page 7

Measurement OperationA. DC/AC Voltage Measurement (See figure 2) figure 2Model UT61A/61B/61C/61D/61E: OPERATING MANUAL15

Page 8

WarningTo avoid harms to you or damages to the Meter from electric shock, please donot attempt to measure voltages higher than 1000V although r

Page 9

Notel In each range, the Meter has an input impedance of 10M except mV range which input impedance is 3000M . This loading effect can cause mea

Page 10

B. DC/AC Current Measurement (See figure 3) figure 3AModel UT61A/61B/61C/61D/61E: OPERATING MANUAL18

Page 11 - Rotary Switch

WarningBefore connecting the Meter to the return circuit to be tested, cut off the currentof the return circuit.If the fuse burns out during mea

Page 12 - Functional Buttons

353738393939404041414142434446495255Title Page I.Transistor hFE Measurement J.EF FunctionOperation of Hold ModeRANGE ButtonMAX MIN ButtonPEAK

Page 13

UT61A, UT61B and UT61C: display effective value of sine wave (meanvalue response).UT61D and UT61E: display true rms value.5. Press Hz% to obtain the

Page 14

C. Measuring Resistance (See figure 4)figure 4Model UT61A/61B/61C/61D/61E: OPERATING MANUAL21

Page 15 - figure 2

WarningTo avoid damages to the Meter or to the devices under test, disconnect circuitpower and discharge all the high-voltage capacitors before m

Page 16

Model UT61A/61B/61C/61D/61E: OPERATING MANUAL23

Page 17

D. Testing for Continuity (See figure 5)figure 5Model UT61A/61B/61C/61D/61E: OPERATING MANUAL24

Page 18 - figure 3

WarningTo avoid damages to the Meter or to the devices under test, disconnect circuitpower and discharge all the high-voltage capacitors before t

Page 19

E. Testing Diodes (See figure 6)figure 6Model UT61A/61B/61C/61D/61E: OPERATING MANUAL26

Page 20

Model UT61A/61B/61C/61D/61E: OPERATING MANUAL27

Page 21

l Connect the test leads to the proper terminals as said above to avoid error display. The LCD will display OL indicating diode being tested is

Page 22

F. Capacitance Measurement (See figure 7)figure 7Model UT61A/61B/61C/61D/61E: OPERATING MANUAL29

Page 23

Title Page5759606061626262636567 F.Capacitance G.Frequency H.Diode Test I.Continuity Test J.Temperature K.Transistor hFEMaint

Page 24

WarningTo avoid damage to the Meter or to the equipment under test, disconnect circuitpower and discharge all high-voltage capacitors before mea

Page 25

figure 8n the tested capacitor is more than 100uFModel UT61A/61B/61C/61D/61E: OPERATING MANUAL31

Page 26

300 For UT61E:Measuring Audio frequency,if the input voltage is more than 15 volt. the meter will simulate the sound in same frequen

Page 27

l When frequency measurement has been completed, disconnect the connectionbetween the testing leads and the circuit under test, and remove the testing

Page 28

WarningTo avoid harm to yourself, do not input higher than DC 60V or AC 30V voltages.To measure temperature, connect the Meter as follows:1. Set the r

Page 29

I. Transistor hFE Measurement (UT61A only) (See figure 10) figure 10Model UT61A/61B/61C/61D/61E: OPERATING MANUAL35

Page 30

1. Set the rotary switch to hFE.2. Insert the multi-purpose socket into the input terminal as shown on figure 10.3. Insert the transistor to be tested

Page 31

J. EF Function (UT61A only) (See figure 11)figure 11Model UT61A/61B/61C/61D/61E: OPERATING MANUAL37

Page 32

To use EF function, connect the Meter as follows:1. Set the rotary switch to EF and remove the test lead from the input terminals.2. Place the housing

Page 33

RANGE buttonl Press RANGE to enter the manual ranging mode; the Meter beeps.l Press RANGE to step through the ranges available for the selected functi

Page 34

This Operating Manual covers information on safety and cautions. Please read therelevant information carefully and observe all the Warnings and Notes

Page 35 - figure 10

For UT61E,Auto entering Data outputting mode.Model UT61A/61B/61C/61D/61E: OPERATING MANUAL40

Page 36

Model UT61A/61B/61C/61D/61E: OPERATING MANUAL41

Page 37

General Specificationsl Maximum Voltage between any Terminals and Grounding: Refer to the different ranges input protection voltage..l Fused Prot

Page 38 - Operation of Hold Mode

Model UT61A/61B/61C/61D/61E: OPERATING MANUAL43

Page 39

Model UT61A/61B/61C/61D/61E: OPERATING MANUAL44

Page 40

(0.8%+3)Model UT61A/61B/61C/61D/61E: OPERATING MANUAL45

Page 41

Model UT61A/61B/61C/61D/61E: OPERATING MANUAL46

Page 42

3Model UT61A/61B/61C/61D/61E: OPERATING MANUAL47

Page 43

Model UT61A/61B/61C/61D/61E: OPERATING MANUAL48

Page 44

Model UT61A/61B/61C/61D/61E: OPERATING MANUAL49

Page 45 - (0.8%+3)

Except where noted, the descriptions and instructions in this Operating Manual applyto all Model UT61A/UT61B/UT61C/UT61D/UT61E.Unpacking InspectionOpe

Page 46

0Model UT61A/61B/61C/61D/61E: OPERATING MANUAL50

Page 47

Model UT61A/61B/61C/61D/61E: OPERATING MANUAL51

Page 48

Model UT61A/61B/61C/61D/61E: OPERATING MANUAL52

Page 49

3Model UT61A/61B/61C/61D/61E: OPERATING MANUAL53

Page 50

10Model UT61A/61B/61C/61D/61E: OPERATING MANUAL54

Page 51

Model UT61A/61B/61C/61D/61E: OPERATING MANUAL55

Page 52

Model UT61A/61B/61C/61D/61E: OPERATING MANUAL56

Page 53

444444Model UT61A/61B/61C/61D/61E: OPERATING MANUAL57

Page 54

Model UT61A/61B/61C/61D/61E: OPERATING MANUAL58

Page 55

3004040040M0.01Hz0.001HzModel UT61A/61B/61C/61D/61E: OPERATING MANUAL59

Page 56

In the event you find any missing or damage, please contact your dealer immediately.Safety InformationThis Meter complies with the standards IEC61010:

Page 57

0.001V0.0001VModel UT61A/61B/61C/61D/61E: OPERATING MANUAL60

Page 58

VacModel UT61A/61B/61C/61D/61E: OPERATING MANUAL61

Page 59

MaintenanceThis section provides basic maintenance information including battery and fusereplacement instruction. WarningDo not attempt to repair

Page 60

l Do not use or store the Meter in a place of humidity, high temperature, explosive, inflammable and strong magnetic field.B. Replacing the Batte

Page 61

WarningTo avoid false readings, which could lead to possible electric shock or personalinjury, replace the battery as soon as the battery indica

Page 62

C. Replacing the Fusesfigure 13Model UT61A/61B/61C/61D/61E: OPERATING MANUAL65

Page 63 - B. Replacing the Battery

WarningTo avoid electrical shock or arc blast, or personal injury or damage to the Meter,use specified fuses ONLY in accordance with the followi

Page 64

USB Serial Port (UT61B, UT61C , UT61D and UT61E only)It is optional at extra cost.Please refer to the ìInstallation Guide & Computer Interface Sof

Page 65 - C. Replacing the Fuses

This operating manual is subject to change without notice.Copyright 2008 Uni-Trend Group Limited.All rights reserved.Manufacturer:Uni-Trend Technology

Page 66

Rules For Safe OperationWarningTo avoid possible electric shock or personal injury, and to avoid possibledamage to the Meter or to the equipment under

Page 67

l Do not use or store the Meter in an environment of high temperature, humidity, explosive, inflammable and strong magnetic field. The performa

Page 68

l Turn the Meter off when it is not in use and take out the battery when not using for a long time.l Constantly check the battery as it may leak

Commentaires sur ces manuels

Pas de commentaire