UNI-T UT501 Manuel d'installation

Naviguer en ligne ou télécharger Manuel d'installation pour Multimètres UNI-T UT501. UNI-T UT501 Unit installation Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 26
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
I/F 501
INTERFACE UNIT
INSTALLATION AND OPERATION GUIDE
Software Revision 1.05, Version A
INTRODUCTION
The I/F 501 interface unit allows a variety of comunication protocals used in NSI and other industrial equipment
to be translated between one another. In addition the I/F 501 can serve as an independent, programmable lighting
controller. The I/F 501 also serves as the interface between NSIs Luma-net network and a personal computer.
SPECIFICATIONS:
Microplex Input (I/O) 3 pin XLR male
Microplex Ouput (I/O) 3 pin XLR female
DMX 512 Input 5 pin XLR male (USITT spec)
DMX 512 Output 5 pin XLR female (USITT spec)
AMX 192 Output (optional, replaces 512) 4 pin XLR female (USITT spec)
RS-232 I/O 9 pin ‘‘D’’ connector
MIDI input / Analog input 5 pin din 180 degree connector
Luma-net I/O Modular style telephone connector
Power requirements +15VDC 200ma (power supply included)
IMPORTANT
Although many different connectors are present on this unit, in most configurations, one or more of the connectors
may serve no function. It is important that the installer verify that the required inputs and outputs operated in the
mode required for the application. Please read the appropriate application sheets in this manual carefully before
installing.
Vue de la page 0
1 2 3 4 5 6 ... 25 26

Résumé du contenu

Page 1 - INTERFACE UNIT

I/F 501INTERFACE UNITINSTALLATION AND OPERATION GUIDESoftware Revision 1.05, Version AINTRODUCTION The I/F 501 interface unit allows a variety of comu

Page 2

MIDI TO AMX-192In this application, MIDI is converted to AMX 192.CONNECTOR OPERATIONMicroplex IN Not usedMicroplex OUT Not UsedDMX IN Not used*DMX out

Page 3 - NSI CORPORATION 3

RS-232 to MICROPLEX and DMX 512In this application, a computer may send simple ASCII commands to operate individual dimmer channels.CONNECTOR OPERATIO

Page 4 - NSI CORPORATION 4

RS-232 TO AMX 192In this application, a personal computer may send ascii commands to operate individual dimmer channels.CONNECTOR OPERATIONMicroplex

Page 5 - NSI CORPORATION 5

LUMA-NET to MICROPLEXIn this application, Microplex or DMX is mixed with LUMA-NET and transmitted as Microplex.CONNECTOR OPERATIONMicroplex IN Input M

Page 6 - NSI CORPORATION 6

LUMA-NET to DMX-512In this application, Microplex or DMX is mixed with LUMA-NET and transmitted as DMX 512.CONNECTOR OPERATIONMicroplex IN Input Micro

Page 7 - NSI CORPORATION 7

LUMA-NET to AMX - 192In this application, Microplex or DMX is mixed with LUMA-NET and transmitted as AMX-192.CONNECTOR OPERATIONMicroplex IN Input Mic

Page 8 - NSI CORPORATION 8

ANALOG TO / MERGED WITH DMX 512 and MICROPLEXIn this application, 0 to 10VDC is converted to Microplex or and DMX 512..CONNECTOR OPERATIONMicroplex I

Page 9 - NSI CORPORATION 9

ANALOG TO AMX-192In this application, 0 - 10VDC is converted to AMX 192.CONNECTOR OPERATIONMicroplex IN Input MicroplexMicroplex OUT Not UsedDMX IN

Page 10 - NSI CORPORATION 10

AUTOCHASE TO MICROPLEX AND DMX 512.In this application, the unit serves as a stand alone chaser.CONNECTOR OPERATIONMicroplex IN Not UsedMicroplex OUT

Page 11 - NSI CORPORATION 11

RS-232 AUTO-CUEING TO MICROPLEX AND DMX.In this application, the unit serves as a stand alone programmable memory lighting controller with precise ti

Page 12 - NSI CORPORATION 12

Front Panel1 DC Power input - Connect 15VDC (+ tip, - ring) 250ma here. (Supplied with unit.)2 Address - Controls translation of adresses (and other s

Page 13 - NSI CORPORATION 13

LUMA-NET 404CP EMULATION WITH EXTERNAL CONTACTS.In this application, the unit serves as a 404CP panel with external contact closures. CONNECTOR OPERAT

Page 14 - NSI CORPORATION 14

LUMA-NET SOFTWARE INTERFACE.This application is for use with the Luma-net Computer Software. This unit serves as the interface between thecomputer a

Page 15 - NSI CORPORATION 15

Lumanet Channel number codes / dipswitch settings.Multiply channel listed by increment required. Subtract one for Luma-net network ID no.0 - switch do

Page 16 - NSI CORPORATION 16

DMX 512 Channel number codes / dipswitch settings.0 - switch down, 1 - switch up1st DMXChannelDipswitch12345671st DMXChannelDipswitch12345671st DMXCha

Page 17 - NSI CORPORATION 17

ASCII Cues ImplementationOverviewFollowing are the rules for editing ASCII Cues as implemented on the IF501, software revision 1.00:If you use a word

Page 18 - NSI CORPORATION 18

DOWNThis keyword specifies the fade down time of the previous cue. This keyword must be followed by a space andthe time in the range of ‘‘0" to

Page 19 - NSI CORPORATION 19

WARRANTYNSI Corporation Limited Warranty NSI Corporation warrants new electronics products to be free from defective materials and workmanship for ape

Page 20 - NSI CORPORATION 20

JUMPER LOCATIONSPCB locations of jumpers / internal connectorsINTERFACE UNITSoftware Revision 1.05, Version A JUMPER LOCATIONSNSI CORPORATION 3

Page 21 - NSI CORPORATION 21

INPUT -> OUTPUTCONFIGSWITCHd-downu-up1234P4P5P7 JP1 JP6JP7JP8JP9JP10 JP11 JP12 DMXOUTCONNDEFAULT SETTINGSdddd OFF ON 6 2-3 2-3 2-3 2-3 1-2 JP4MPX -

Page 22 - NSI CORPORATION 22

PINOUTS Pinouts of the various connectorsINTERFACE UNITSoftware Revision 1.05, Version A PINOUTS NSI CORPORATION 5

Page 23 - NSI CORPORATION 23

MICROPLEX TO DMX 512In this application, Microplex is converted to DMX-512. The Microplex is then retransmitted.CONNECTOR OPERATIONMicroplex IN Input

Page 24 - NSI CORPORATION 24

MICROPLEX TO AMX 192In this application, Microplex is converted to AMX-192. The 5 pin XLR may be replaced with a 4 pin XLR(USITT) if desired.CONNECTO

Page 25 - NSI CORPORATION 25

DMX 512 TO MICROPLEXIn this application, DMX 512 is converted to Microplex..CONNECTOR OPERATIONMicroplex IN Not usedMicroplex OUT Output Microplex (64

Page 26 - WARRANTY

MIDI TO MICROPLEX and DMX 512In this application, MIDI note commands are converted to Microplex and DMX 512 dimmer levels.CONNECTOR OPERATIONMicroplex

Commentaires sur ces manuels

Pas de commentaire